BNMMP - 711175 QUANTAB CHLORIDE TITRATOR

Product Identification

Product ID:711175 QUANTAB CHLORIDE TITRATOR
MSDS Date:09/20/1993
FSC:6850
NIIN:00-180-6165
MSDS Number: BNMMP

Responsible Party
ENVIRONMENTAL TEST SYSTEMS INC
23575 COUNTY RD 106
ELKHART, IN 46514-0659
US

Emergency Phone: 219-262-2060

Info Phone: 219-262-2060

Cage: 1BY35

Contractor
ENVIRONMENTAL TEST SYSTEMS INC
4659 ELKHART, IN 46514-0659 US

Telephone: 219-262-2060

Cage: 1BY35

Ingredients

POTASSIUM BICHROMATE (SARA III)

CAS: 7778-50-9

RTECS: HX7680000

OSHA PEL C,0.1 MG/M3 CRO3

ACGIH TLV: 0.5 MG CR/M3; 9293

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 190MG/KG K*2CR*2O*7
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:PRODUCT CONTAINS A LOW LEVEL OF
CARCINOGENIC HEXAVALENT CHROMIUM (LESS THAN 0.01% BY WEIGHT IN AN
INDIVIDUAL TITRATOR) AND, THEREFORE, IS CONSIDERED TO BE
NON-HAZARDOUS. ABSORPTION THROUGH SKIN CAN CA USE SYSTEMIC
POISONING & ECZEMATIC DERMATITIS. EXPOSURE UNLIKELY SINCE CHEMICAL
IS SEALED IN A LAMINATED SHEATH.
Explanation of Carcinogenicity:CHROMIUM (VI) IS LISTED AS A HUMAN
CARCINOGEN.
Effects of Overexposure:IRRITATION, NAUSEA AND VOMITING.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE PRE-EXISTING SKIN
DISORDERS.

First Aid

First Aid:SKIN:WASH AFFECTED PARTS THOROUGHLY. INGEST:CONSULT
PHYSICIAN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:FLOOD WITH LARGE AMOUNTS OF WATER.DO NOT ALLOW
WATER TO ENTER SEWER.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:MANUFACTURER STATES NONE KNOWN.

Accidental Release

Spill Release Procedures:PICK UP;REUSE OR DISPOSE OF.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:KEEP MATERIAL DRY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT NEEDED IN NORMAL SERVICE.
Ventilation:USE GENERAL DILUTION VENTILATION.
Protective Gloves:NOT NEEDED IN NORMAL SERVICE.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE
Work Hygienic Practices:DO NOT DISASSEMBLE DEVICE OR EXPOSE CHEMICAL
STRIP.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:932F,500C
Solubility in Water:NEGLIGIBLE
Appearance and Odor:ORANGE-RED PAPER STRIP LAMINATED WITHIN A PLASTIC
SHEATH, ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
REDUCING AGENTS AND COMBUSTIBLES.
Stability Condition to Avoid:HIGH HEAT,SOURCES OF IGNITION.
Hazardous Decomposition Products:TOXIC CHROMIUM TRIOXIDE FUMES.

Disposal

Waste Disposal Methods:DISPOSE OF AS RCRA WASTE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.